{"product_id":"southwire-10-2uf-w-gx25-type-uf-b-copper-building-wire-gray-pvc-10-2-25","title":"Southwire 10\/2UF-W\/GX25 Type UF-B Copper Building Wire, Gray PVC, 10\/2, 25'","description":"\u003cp style=\"text-align: justify;\"\u003e\u003cspan style=\"color: #000000;\"\u003eSouthwire Type UF-B cable is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building as specified in the National Electrical Code.1 UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code. UF-B can be used in applications permitted for NMC in Section 334.10(B) of the National Electrical Code. Voltage rating for UF-B cable is 600 volts.\u003c\/span\u003e\u003c\/p\u003e\r\n\u003cul style=\"text-align: justify;\"\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eUnderground Feeder and Branch Circuit Cable\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCopper Conductors\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eSunlight, Moisture, and Fungus Resistant Overall PVC Jacket\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eType THHN insulation, rated 90 degrees Celsius, 600 volt. \u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eGray PVC jacket\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eFlame retardant, moisture, fungus, and corrosion resistant.\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eSunlight resistant jacket.\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eFor applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring.\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eJC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002.\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eUL Listed.\u003c\/span\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cspan style=\"font-size: medium; color: #800000;\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\r\n\u003cul style=\"text-align: justify;\"\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eType: UF-B \u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eConductor Size: 10 AWG\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eNumber of Conductors: 2 \u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eConductor Material: Copper \u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLength: 25 ft\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eStrands: 1 \u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAmperage Rating: 30 A\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eVoltage Rating: 600 V\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eInsulation Type: PVC \u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eJacket Type: Nylon \u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eJacket Color: Gray \u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eTemperature Rating: 90 deg C\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eStandards: UL Listed \u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eUsage: Used as feeder to outside post lamps, pumps and other loads.\u003c\/span\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e","brand":"Southwire","offers":[{"title":"Default Title","offer_id":12600836423743,"sku":"12029091","price":79.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2196\/8707\/products\/4fa2eed0b8a67f715396815d394aad5f_7eb60fbf-50dc-4e1f-b206-b286379f02ba.jpg?v=1571723394","url":"https:\/\/tuolboxsupply.com\/products\/southwire-10-2uf-w-gx25-type-uf-b-copper-building-wire-gray-pvc-10-2-25","provider":"Toolbox Supply","version":"1.0","type":"link"}